Rev. chil. radiol ; 22(4): 158-163, 2016. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-844622

RESUMO

Abstract: Objective. Assess the performance of digital 2D mammography and tomosynthesis in the characterisation of architectural breast distortion (ABD). Material and method. A retrospective study, approved by the Ethics Committee, was conducted on mammographic studies on cases with a diagnosis of ABD selected from August 2015-August 2016. Cases with imaging modalities available on PACS were included: digital mammography (2D), tomosynthesis (TS), ultrasound (US), magnetic resonance (MR), and with biopsy performed at our institution. ABD cases associated with micro-calcifications and post-surgical changes were excluded. Detection rates and imaging characteristics were analysed, as well as the histopathological concordance. Results. A total of 81 cases of ABD without microcalcifications were detected on the mammographs, but only 52 met the inclusion criteria. According to histopathology, 23 (44%) were malignant, 17 (33%) were benign, and 12 (23%) were high-risk lesions. All were detected by TS and US, and classified as suspicious lesions (BI-RADS 4 or 5). In 2D mammography, 24 cases (46%) were not seen and 8 (33%) of these were malignant. Malignant lesions showed dense centres in 87% of cases. The most frequent lesion on ultrasound was a hypoechogenic area (60%) in 86% of lesions with penetrating vessels. A total of 21 MRI were performed, with mass enhancement being identified in all of them. Conclusion. ABD is better displayed in TS than 2D mammography. Despite its characteristics, histological examination is essential (even when a radiolucent centre is observed). Focused US should be the next procedure to follow, since it allows to visualize the lesion to be visualised, and can direct the percutaneous biopsy in most cases.


Resumen: Objetivo. Determinar en qué método de imagen se logra visualizar y caracterizar mejor una distorsión de la arquitectura mamaria (DAM). Material y método. Estudio retrospectivo, aprobado por el Comité de Ética. Se seleccionaron los estudios mamográficos con diagnóstico de DAM en nuestro servicio entre agosto de 2015 y agosto de 2016. Se incluyeron casos estudiados con al menos 3 de las modalidades de imágenes disponibles en PACS: mamografía digital (2D), tomosíntesis (TS), ecografía (US), resonancia (RM) y que fueron biopsiados en nuestra institución. Se excluyeron casos de DAM asociadas con microcalcificaciones y cambios posquirúrgicos. Se evaluaron la tasa de detección, las características imagenológicas y la concordancia histopatológica. Resultados. En 15 meses se detectaron 81 casos de DAM en mamografía; de estos, 52 cumplieron con los criterios de inclusión. Según la histopatología, 23 (44%) resultaron malignas, 17 (33%) benignas y 12 (23%) lesiones de alto riesgo (LAR). Todas fueron detectadas por TS y US, clasificadas como lesiones sospechosas (BI-RADS 4 o 5). En mamografía 2D, 24 casos (46%) quedaron ocultos, y de estos, 8 (33%) resultaron malignos. Las lesiones malignas presentaron centro denso en el 87% de los casos. La lesión más frecuente en ecografía fue el área hipoecogénica (60%), en el 86% de las lesiones con vasos penetrantes. Se contó con 21 RM, identificándose captación tipo masa en las patologías malignas. Conclusión. La DAM es mejor visualizada en TS que en mamografía 2D. Pese a sus características, un estudio histológico es indispensable (incluso al observar un centro radiolúcido). El US dirigido es el paso a seguir, ya que permite visualizar la lesión y dirigir su biopsia percutánea en la mayoría de los casos.


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mama/patologia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Mamografia , Lesões Pré-Cancerosas/patologia , Estudos Retrospectivos
2.
Rev. chil. radiol ; 7(3): 86-89, 2001. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-317409

RESUMO

Se presenta una comunicación preliminar de la experiencia con el uso del Mammotome bajo estereotáxia para biopsia mamaria en 115 pacientes con 128 lesiones, realizadas en el Servicio de imagenología mamaria de la Clínica Alemana de Santiago entre agosto de 1999 y agosto del 2000


Assuntos
Humanos , Adulto , Feminino , Idoso , Pessoa de Meia-Idade , Biópsia por Agulha , Doenças Mamárias , Técnicas Estereotáxicas/instrumentação , Procedimentos Cirúrgicos Ambulatórios/instrumentação
3.
Rev. chil. radiol ; 7(1): 5-7, 2001. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-295354

RESUMO

La enfermedad de Mondor consiste en una tromboflebitis de las venas subcutáneas de la región toracoabdominal anterolateral. Es una entidad poco frecuente, descrita por primera vez por Fagge en 1870 y caracterizada por Mondor en 1939 (1,2). La causa no ha sido establecida, pero su aparición se ha asociado a trauma local, cirugía, infección, embarazo, lactancia, exceso de ejercicio físico, mamas grandes y péndulas y a alteraciones inmunológicas (3,4). También está descrita su aparición en concomitancia con ganglios axilares metastásicos y cáncer de mama. Esta última coexistencia llega hasta un 12 por ciento de los casos en una serie publicada (5-8). Afecta mayoritariamente a mujeres en una proporción de 3 de por cada hombre. Se presenta en la edad media de la vida, puede ser ocacionalmente bilateral y también hay descritos casos de recurrencia (3,4,9)


Assuntos
Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Tromboflebite , Ultrassonografia Doppler em Cores , Neoplasias da Mama/complicações , Dermatopatias , Tromboflebite/etiologia , Tromboflebite/fisiopatologia , Ultrassonografia Doppler em Cores/estatística & dados numéricos
4.
Rev. chil. radiol ; 6(4): 141-7, 2000. ilus
Artigo em Espanhol | LILACS | ID: lil-295369

RESUMO

Los avances tecnológicos de los últimos años en la resonancia magnética (RM) y la utilización de medio de contraste paramagnético han significado un gran impacto en la imagenología mamaria, especialmente en la evaluación preoperatoria del cáncer y en el seguimiento de los pacientes tratados por el cáncer de mama. En este artículo se resumen los aspectos técnicos de la realización de una RM mamaria, se detallan las principales indicaciones y se mencionan las futuras aplicaciones posibles


Assuntos
Humanos , Feminino , Neoplasias da Mama/diagnóstico , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Implantes de Mama/efeitos adversos , Neoplasias da Mama , Quimioterapia Adjuvante , Espectroscopia de Ressonância de Spin Eletrônica , Mamografia , Sensibilidade e Especificidade